# BMS London > Building management system (BMS) installation, servicing, maintenance, repair, upgrades and controls optimisation for commercial buildings across Greater London, from Flair Facilities Ltd. BMS London is the building management systems (BMS) website of Flair Facilities Ltd, a commercial mechanical and controls engineering company based at 24 Kemp House, 152 City Road, London EC1V 2NX. It covers all 32 London boroughs and the City of London. Key facts: - Company: Flair Facilities Ltd, registered in England and Wales, Companies House number 14816195, VAT GB467203885 - Telephone: 020 7998 9005 (+44 20 7998 9005) - Email: info@flairfacilities.co.uk - Quote requests: https://flairfacilities.co.uk/contact-us/ - Main company website: https://flairfacilities.co.uk/ - BMS platforms and protocols: open-protocol systems including Trend, Tridium (Niagara) and Honeywell; integration over BACnet, Modbus, MQTT and DALI - Works on systems installed by other contractors where they use standard protocols - Gas Safe registration 970944 applies to Flair's gas work, not to BMS work ## BMS services - [BMS Installation in London](https://bms-london.bms-london.workers.dev/bms-installation/): Building management system installation across Greater London: controls design, custom control panels, wiring, open-protocol integration and commissioning. - [BMS Servicing and Maintenance in London](https://bms-london.bms-london.workers.dev/bms-maintenance/): Planned BMS servicing and maintenance contracts across Greater London: back-ups, sensor calibration, alarm and override reviews, interlock tests and reporting. - [BMS Repair and Fault Finding in London](https://bms-london.bms-london.workers.dev/bms-repair/): BMS repair and fault finding across Greater London: failed controllers, sensors, actuators, communications and front-ends diagnosed and put right. - [BMS Upgrades and Integration in London](https://bms-london.bms-london.workers.dev/bms-upgrades/): BMS upgrades across Greater London: legacy outstation replacement, open-protocol integration of boilers and HVAC, and phased migration that keeps plant running. - [BMS Controls Optimisation in London](https://bms-london.bms-london.workers.dev/bms-optimisation/): BMS and controls optimisation across Greater London: schedules, setpoints, deadbands, weather compensation, alarm review and control loop tuning. - [All BMS services](https://bms-london.bms-london.workers.dev/services/): Overview of the five BMS services and Flair Facilities Ltd's wider mechanical services. ## Company and coverage - [About](https://bms-london.bms-london.workers.dev/about/): Who Flair Facilities Ltd is, how the team works, sectors served and company details. - [Areas we cover](https://bms-london.bms-london.workers.dev/areas/): BMS services in all 32 London boroughs and the City of London. - [Contact and quotes](https://bms-london.bms-london.workers.dev/contact/): Quote request form, telephone 020 7998 9005, email info@flairfacilities.co.uk and office location. ## Technical guides - [Building Management Systems: Monitoring, Controls and Fault Diagnosis](https://bms-london.bms-london.workers.dev/building-management-systems/): What a BMS does, how sensors, controllers and outstations work together, and how to diagnose faults, manage alarms and use trend logs. - [Commercial Boilers: Troubleshooting, Lockouts and Maintenance](https://bms-london.bms-london.workers.dev/commercial-boilers/): Understand commercial boiler lockouts, pressure problems, cascade operation and servicing requirements. A practical UK guide for facilities managers. - [Commercial Gas and Flue Systems: Duties, Risks and Records](https://bms-london.bms-london.workers.dev/commercial-gas-and-flues/): Commercial gas safety responsibilities, gas safety records, boiler flue systems, fan dilution and catering gas interlocks explained for UK facilities managers. - [Commercial Heating Systems: How They Work and Why They Fail](https://bms-london.bms-london.workers.dev/commercial-heating/): How commercial heating systems work, why they fail and how UK facilities managers can diagnose comfort complaints, improve efficiency and plan maintenance. - [Commercial HVAC Systems: A Practical Guide to Faults and Maintenance](https://bms-london.bms-london.workers.dev/commercial-hvac/): How commercial HVAC systems work, including AHUs, fan coil units, VRF and ventilation, plus common faults, UK compliance duties and maintenance priorities. - [Commercial Pipework and Insulation: What Facilities Managers Should Know](https://bms-london.bms-london.workers.dev/commercial-pipework/): A guide to commercial heating and chilled water pipework, corrosion and leak causes, insulation standards and asbestos risks for UK facilities managers. - [Emergency Mechanical Fault Guidance for Commercial Buildings](https://bms-london.bms-london.workers.dev/emergency-mechanical-faults/): A first-response guide for facilities managers facing heating loss, gas smells, major leaks, plant room alarms or ventilation failure in commercial buildings. - [Facilities Management Guides for Mechanical Building Services](https://bms-london.bms-london.workers.dev/facilities-management-guides/): Practical facilities management workflows for mechanical services: compliance files, contractor management, fault reporting, and preparing for engineer visits. - [Commercial Building Engineering in Greater London](https://bms-london.bms-london.workers.dev/london-commercial-engineering/): How Greater London's building stock shapes mechanical engineering: basement plant rooms, tall buildings, heritage limits, heat networks and access. - [Planned Preventative Maintenance for Commercial Mechanical Services](https://bms-london.bms-london.workers.dev/planned-preventative-maintenance/): How to plan mechanical PPM in a commercial building: asset registers, SFG20 frequencies, statutory versus recommended tasks and practical schedules. - [Plant Room Engineering: Equipment, Interactions and Inspection](https://bms-london.bms-london.workers.dev/plant-room-engineering/): What is in a commercial plant room, how boilers, pumps, headers, vessels and controls work together, and a practical plant room inspection checklist for FMs. - [Water Pressure and Pumps in Commercial Buildings](https://bms-london.bms-london.workers.dev/water-pressure-and-pumps/): How booster sets, pressurisation units and calorifiers keep commercial buildings supplied with water, and how to diagnose low pressure and pump problems. ## Articles - [BMS Alarm Management: Making Alarms Useful Again](https://bms-london.bms-london.workers.dev/insights/bms-alarm-management/): How to structure BMS alarm priorities, cut nuisance alarms, and make sure critical building services faults are seen and acted on quickly. A guide for FMs. - [BMS Temperature Sensor Faults: How to Spot and Diagnose Them](https://bms-london.bms-london.workers.dev/insights/bms-temperature-sensor-faults/): How faulty BMS temperature sensors cause comfort complaints and energy waste, how to spot drift and failure in trend logs, and when to recalibrate or replace. - [Commercial Boiler Lockout: Common Causes and What to Check](https://bms-london.bms-london.workers.dev/insights/commercial-boiler-lockout-causes/): Why commercial boilers lock out, what common fault categories mean, what facilities managers can safely check, and when to call a Gas Safe registered engineer. - [Commercial Gas Safety Responsibilities and Documentation for Facilities Managers](https://bms-london.bms-london.workers.dev/insights/commercial-gas-safety-responsibilities/): What UK facilities managers must do to meet commercial gas safety duties: who is responsible, which records to keep, competence checks and remedials. - [Why Is My Commercial Heating System Losing Pressure?](https://bms-london.bms-london.workers.dev/insights/commercial-heating-system-losing-pressure/): Common causes of pressure loss in sealed commercial heating systems, from leaks and expansion vessel failure to pressurisation unit faults. - [AHU Troubleshooting: Diagnosing Air Handling Unit Faults](https://bms-london.bms-london.workers.dev/insights/ahu-troubleshooting-guide/): Diagnose common air handling unit faults: low airflow, supply temperature problems, frost trips, filter alarms, noisy fans and heat recovery issues. - [Commercial Mechanical PPM Checklist](https://bms-london.bms-london.workers.dev/insights/mechanical-ppm-checklist/): A practical mechanical PPM checklist for UK commercial buildings: heating, HVAC, water, BMS and gas assets with typical frequencies and records. - [Commercial Circulation Pump Failure: Warning Signs and Causes](https://bms-london.bms-london.workers.dev/insights/commercial-circulation-pump-failure/): Why commercial heating and chilled water circulation pumps fail, early warning signs such as noise and vibration, duty/standby changeover and pump maintenance. - [Low Water Pressure in Commercial Buildings: Causes and Booster Pump Problems](https://bms-london.bms-london.workers.dev/insights/low-water-pressure-commercial-building/): Diagnose low or fluctuating water pressure in commercial buildings, from booster pump problems and break tank issues to blocked strainers and pressure zoning. - [Pressurisation Unit Faults in Commercial Heating and Cooling Systems](https://bms-london.bms-london.workers.dev/insights/pressurisation-unit-faults/): Why commercial pressurisation units alarm, cycle or fail to hold pressure, how they interact with expansion vessels, and what maintenance keeps them reliable. ## Optional - [Full site content for LLMs](https://bms-london.bms-london.workers.dev/llms-full.txt): Every service page, guide and article as plain Markdown in one file. - [Privacy policy](https://bms-london.bms-london.workers.dev/privacy-policy/): How this website handles personal data. - [Terms and conditions](https://bms-london.bms-london.workers.dev/terms-and-conditions/): Website terms of use. - [Sitemap](https://bms-london.bms-london.workers.dev/sitemap-index.xml): XML sitemap of every page.