Whoever controls gas appliances and installation pipework in commercial premises must keep them safe and properly maintained under the Gas Safety (Installation and Use) Regulations 1998 and wider health and safety law. For a facilities manager that means using only Gas Safe registered engineers with the right non-domestic competencies, scheduling regular safety inspections and servicing, acting on defects promptly, and keeping a complete, accessible record of every check, test and repair.
Who is responsible for gas safety in commercial premises?
Duties sit with whoever has control of the premises, the appliances or the installation pipework. In a single-occupier building this is usually the employer. In multi-let buildings responsibility is often split: the landlord may control central boiler plant and risers while tenants control kitchen appliances in their demise. Leases and service agreements should make this explicit.
Facilities managers commonly act as the responsible person on behalf of the duty holder. That role is about managing competent contractors and keeping records, not carrying out gas work.
What does “competent” mean for commercial gas work?
Anyone working on gas fittings for gain must be on the Gas Safe Register, and must hold the specific competencies for the work. Commercial categories differ from domestic ones, covering items such as non-domestic boilers, commercial catering appliances, large pipework and tightness testing. Before work:
- Check the engineer on the Gas Safe Register website
- Check the back of their ID card lists the relevant non-domestic categories
- Keep a copy of competency evidence with the contractor’s RAMS
Which records should a facilities manager hold?
| Record | What it shows | Typical trigger |
|---|---|---|
| Gas safety inspection record | Appliance and installation checked as safe | Annually, or as specified |
| Service report | Appliance serviced, combustion readings | Per manufacturer and PPM schedule |
| Tightness test record | Pipework tested gas-tight | After work on pipework, or periodically |
| Purge record | Pipework safely purged | After new installation or major works |
| Catering inspection record (often called CP42) | Catering appliances, ventilation and interlock checked | Annually, or as specified |
| Interlock test record | Gas shuts off if ventilation or fan dilution fails | With inspection or service |
| Warning notices | Defects classified as at risk or immediately dangerous | When defects found |
| Remedial completion record | Defect corrected and verified | After remedial work |
| Installation schematic | Meter, ECVs, isolations, routes | Kept current |
What are the common gaps?
- Inspection records that list some appliances but miss others, such as a small water heater or a roof-top unit
- Warning notices issued but no evidence the defect was put right
- Catering interlocks not tested or recorded
- Records held only by a former contractor
- No schematic showing where emergency control valves are
- Engineers whose card does not cover the work they carried out
How should defects be handled?
Engineers classify defects under the industry unsafe situations procedure, typically as immediately dangerous, at risk or not to current standards. Your process should:
- Record each defect with its classification, date and asset.
- Confirm any disconnection and warning labels are in place.
- Obtain a remedial quote and approve it promptly.
- Prevent reconnection until the engineer certifies the remedy.
- File the completion record alongside the original report.
Safety: Do not allow appliances labelled “Do not use” to be reconnected or used before remedial work is completed by a Gas Safe registered engineer. If anyone smells gas or reports carbon monoxide symptoms, follow your gas emergency procedure and call the National Gas Emergency Service on 0800 111 999.
When should you involve a commercial gas engineer?
For every inspection, service, repair and alteration to gas appliances, pipework, flues or interlocks; before reinstating plant after a long shutdown; and whenever building alterations might affect ventilation or flue terminals. Also bring one in for a records audit when taking over a building with incomplete history.
Practical recommendations for facilities managers
- Build a gas asset list covering every appliance, meter and ECV
- Create a single compliance folder for gas records, organised by asset
- Track inspection due dates in your CAFM system or calendar
- Verify engineer competence for each job, not just each contractor
- Close out warning notices with documented completion records
- Test catering and fan dilution interlocks and record the results
For flue arrangements and emergency procedures, see the Commercial Gas and Flues guide. For organising all compliance records, see Facilities Management Guides.
Frequently asked questions
Is an annual gas safety check a legal requirement for a business?
The legal duty is to maintain gas appliances and pipework in a safe condition. There is no single named certificate for most commercial premises, but annual inspection with written records is the normal way to show the duty is met, and insurers, landlords and leases often require it.
What does 'immediately dangerous' mean on a gas report?
It is a classification under the Gas Industry Unsafe Situations Procedure meaning the installation presents an immediate risk. The engineer will normally disconnect it with the responsible person's permission. It must not be reconnected until the defect is put right.
What is a CP42?
CP42 is widely used in the trade as the name of the commercial catering gas safety inspection record. It documents the inspection of catering appliances, ventilation and interlocks. Check your engineer is registered for the catering categories they are inspecting.
How long should gas safety records be kept?
Keep records for the life of the installation where practicable, and at minimum long enough to show a full history of inspection and maintenance. Insurers and auditors frequently ask for several years of records.
UK technical references
Primary sources and industry guidance relevant to this topic. Always check you are working to the current edition.
- Gas Safety (Installation and Use) Regulations 1998 — legislation.gov.uk
- Gas safety: guidance for employers and businesses — Health and Safety Executive
- Gas Safe Register: check an engineer — Gas Safe Register
- Health and Safety at Work etc. Act 1974 — legislation.gov.uk
- Catering and hospitality guidance — Health and Safety Executive
This guide is general technical information for commercial property teams in the UK. It does not replace a site-specific assessment. Gas work must be carried out by a Gas Safe registered engineer, and work on electrical, pressurised or combustion equipment by competent, appropriately qualified people.