BMS upgrades & integration · Greater London

BMS Upgrades and Integration in London

Replace obsolete controllers, bring separate systems onto one front-end and move to open protocols, in planned phases that keep the building running.

  • BMS with obsolete or unsupported controllers
  • Buildings with several separate control systems
  • Sites locked into a single supplier
  • Plant replacements needing new controls interfaces
Diagram showing a legacy outstation replaced by a new open-protocol controller, with BACnet, Modbus, MQTT and DALI labels Original diagram. A dashed box labelled legacy outstation with obsolete spares points by an orange arrow to a new controller that reuses existing field wiring where sound. Four protocol labels sit below. LEGACY OUTSTATION → OPEN-PROTOCOL CONTROLLER Legacyoutstationobsolete spares New controllerexisting field wiringre-used where sound BACnetModbusMQTTDALI Phased changeover keepsplant running throughout
In short

A BMS upgrade replaces ageing parts of a building management system, typically legacy outstations, front-end software or network infrastructure, with modern controllers on open protocols. Integration connects plant and systems that currently run separately, such as boilers, chillers, AHUs, pumps and lighting, so they can be monitored and controlled from one interface. Existing sound field wiring and devices can often be reused, which reduces cost and disruption.

What's included

BMS upgrades & integration: scope of work

  • 01

    Legacy outstation replacement

    Obsolete outstations replaced with modern, faster controllers, reusing sound field wiring where possible.

  • 02

    Front-end upgrades

    Supervisor software and graphics brought up to date, with secure web-based access.

  • 03

    Open-protocol integration

    Plant and systems connected over BACnet, Modbus, MQTT or DALI, with protocol conversion where needed.

  • 04

    Layered integration

    Smart controls added to existing plant without replacing the plant itself.

  • 05

    Phased migration

    Changeover planned system by system, so heating, cooling and ventilation keep running.

  • 06

    Updated documentation

    New points list, control strategy and drawings that reflect the upgraded system.

Signs your BMS needs upgrading

  • Spare parts for controllers are hard to find or no longer made
  • The front-end runs on unsupported software or a single old PC
  • Only one contractor can work on the system
  • Plant from different eras runs on separate, unconnected controls
  • Engineers spend visits working around limitations rather than fixing faults
  • You cannot get the energy or trend data you need

Upgrade options

ApproachWhat changesBest when
Targeted replacementFailed or obsolete controllers onlyMost of the system is sound
Front-end upgradeSupervisor, graphics, remote accessControllers are current but the interface is not
Full migrationControllers, front-end and networkThe system is end-of-life throughout
Layered integrationAdds controls to existing plantPlant is staying but needs central control

We explain the cost and risk of each approach for your building, rather than defaulting to the biggest job.

Integrating separate systems

Many London buildings have accumulated controls over decades: a boiler sequencer from one refurbishment, AHU controls from another, standalone chiller panels and lighting on its own system. Smart building integration connects them over open protocols so they report to one front-end, share schedules and interlocks, and record data in one place. See the BMS and building controls guide for how the layers fit together.

Safety: Changeover of live controls is planned with the site, with safe isolation and temporary arrangements so that frost protection, fire interlocks and other safety functions remain in place throughout.

After the upgrade

An upgraded system needs maintaining like any other. Our BMS servicing and maintenance keeps it backed up and calibrated, and controls optimisation makes sure the new capability is actually used.

How it works

Our process

  1. Step 1

    System audit

    Existing controllers, wiring, network, plant interfaces and documentation assessed.

  2. Step 2

    Upgrade plan

    Options compared, from targeted replacement to full migration, with phasing.

  3. Step 3

    Phased changeover

    Controllers swapped and recommissioned in planned windows.

  4. Step 4

    Recommission and train

    Points re-tested, graphics updated and operators shown the new system.

flairfacilities.co.uk

More on bms upgrades & integration from Flair Facilities

BMS upgrades & integration: questions

Do we have to replace the whole BMS?

Usually not. Many upgrades replace controllers and front-end software while reusing existing sensors, actuators and cabling that are in good condition. An audit tells you which parts are worth keeping.

Will the building lose heating or cooling during an upgrade?

Upgrades are phased so that each system is changed over in a planned window, typically out of hours, with temporary control or manual operation arranged where needed.

What does open protocol mean, and why does it matter?

Open protocols such as BACnet and Modbus are published standards that many manufacturers support. A system built on them can be maintained and extended by any competent controls contractor, so you are not locked in to one supplier.

Can you integrate lighting and metering as well as HVAC?

Lighting systems using DALI, and meters with Modbus or similar interfaces, can typically be brought onto the BMS so energy use and operation can be seen in one place.

Can you upgrade a BMS in a listed or heritage building?

Yes. Upgrades often suit heritage buildings because reusing existing cable routes and adding wireless or small-format devices limits physical intervention. Any work affecting the fabric of a listed building needs the appropriate consents.

UK technical references

Primary sources and industry guidance relevant to this topic. Always check you are working to the current edition.

  1. BACnet International — BACnet International
  2. Approved Document L: Conservation of fuel and power — GOV.UK
  3. Building Controls Industry Association — BCIA